FST-3000 AC Soft Starters Built in Bypass Motor Starter 5.5kW-630kW

Place of Origin:Made in China
Brand Name:AnyHz
Model Number:FST-3000 Series
Minimum Order Quantity:1
Payment Terms:T/T
Product Details
Highlight:

AC Soft Starter 5.5kW

,

Built in Bypass Motor Starter

,

Soft Starters 630kW

Power Range: 5.5kW-630kW
Name: FST-3000 AC Soft Starters Built In Bypass Motor Starter 5.5kW-630kW
Product Description

Soft Starters | FST-3000 Serise Built-in Bypass Motor Starter 5.5kW-630kW

Soft Starters Built-in Bypass 5.5kW-630kW Intelligent Starting
The Anyhz FST-3000 is a new generation built-in bypass soft starter designed for 3-phase AC induction motors from 5.5kW to 630kW. This innovative motor soft starter integrates the bypass contactor and thermal overload relay internally—eliminating external components, reducing panel size by 40%, and simplifying installation.
Unlike traditional soft starters that require separate bypass contactors, the FST-3000's built-in bypass design automatically transfers the motor to line power after starting, minimizing heat generation and energy loss during run mode. With 6 intelligent starting modes, comprehensive protection functions, and LCD display with Chinese/English interface, this electronic soft starter provides smooth, controlled acceleration while reducing starting current by 60-70%—protecting mechanical equipment and extending motor life.
Why Choose FST-3000 Soft Starters?
  • All-in-One Design: Built-in bypass contactor + thermal relay reduces external wiring and panel space by 40%
  • 6 Starting Modes: Current limiting, voltage ramp, kick start, and more for any soft starter application
  • Smart Stop Functions: Free stop, soft stop, and DC braking for controlled deceleration
  • Comprehensive Protection: Input/output phase loss, overload, overcurrent, imbalance, over/undervoltage, overheating
  • Easy Operation: Large LCD display shows current, voltage, faults, and parameters in Chinese or English
  • Communication Ready: Modbus RTU standard for remote monitoring and SCADA integration
  • Wide Power Range: 5.5kW to 630kW covers applications from pumps to large compressors
  • High Efficiency: >99.5% efficiency in bypass mode with near-zero power loss
Advanced Soft Starter Technology
Built-in Bypass Contactor
The integrated bypass contactor eliminates the need for external contactors and wiring traditionally required with motor soft starters. After the motor reaches full speed, the internal contactor automatically bypasses the thyristor power stage, running the motor directly on line power.
  • Electromechanical bypass contactor rated for continuous duty
  • Automatic transfer at 95-98% of nominal speed
  • Zero power loss in bypass mode (vs 2-4% with solid-state only)
  • Thyristor protection during bypass operation
Integrated Thermal Overload Relay
The built-in electronic thermal relay provides Class 10 motor protection without external overload relays. Using advanced thermal modeling algorithms, this intelligent soft starter calculates motor heating based on actual current and time.
  • Class 10A, 10, 20, 30 trip curves selectable
  • Phase imbalance and single-phasing protection
  • Ground fault detection (GF option)
  • PTC/NTC thermistor input for bearing/winding protection
Six Intelligent Starting Modes
The FST-3000 soft starter offers six starting modes to match any application requirement: Current limiting start for maximum current control; Voltage ramp start for smooth acceleration; Kick start for high-friction loads; Current ramp start for precise torque control; Jog/inching for positioning; and Swing start for conveyor applications.
  • Current limiting: 50-600% FLA adjustable
  • Voltage ramp: 1-120 seconds ramp time
  • Kick start: 0-2 seconds at 70-90% voltage
  • Soft stop: 1-60 seconds deceleration control
  • DC braking: 0-20 seconds for fast stopping
Soft Starter Applications
Centrifugal Pumps FST-3000 AC Soft Starters Built in Bypass Motor Starter 5.5kW-630kW 0
Centrifugal pumps benefit from soft starting by eliminating water hammer and pressure surges that damage pipes and valves. The current limiting start reduces inrush to 3-4× FLA (vs 6-8× with direct-on-line), preventing voltage dips that affect other equipment.
Key benefits: Eliminates water hammer, prevents pressure surges, dry-run protection, voltage dip mitigation
Typical configuration: 15kW-315kW for municipal and industrial pumps
Recommended soft starter models: FST-3015 (15kW), FST-3075 (75kW), FST-3155 (160kW)
Fans & Blowers FST-3000 AC Soft Starters Built in Bypass Motor Starter 5.5kW-630kW 1
Large fans and blowers have high inertia that causes belt squeal and mechanical stress during direct starting. The voltage ramp start of this motor soft starter provides smooth acceleration, eliminating belt slip and extending bearing life.
Key benefits: Eliminates belt squeal, reduces bearing stress, smooth acceleration, adjustable ramp time
Typical configuration: 22kW-500kW for HVAC and industrial fans
Recommended soft starter models: FST-3022 (22kW), FST-3110 (110kW), FST-3500 (500kW)
Air Compressors FST-3000 AC Soft Starters Built in Bypass Motor Starter 5.5kW-630kW 2
Air compressors require high starting torque to overcome initial compression. The kick start mode of this electronic soft starter provides the initial torque boost, then transitions to smooth ramping—eliminating mechanical shock that damages couplings and gears.
Key benefits: High starting torque, eliminates mechanical shock, soft stop prevents reverse rotation
Typical configuration: 30kW-400kW for industrial compressors
Recommended soft starter models: FST-3030 (30kW), FST-3090 (90kW), FST-3200 (200kW)
Conveyors & Crushers FST-3000 AC Soft Starters Built in Bypass Motor Starter 5.5kW-630kW 3
Conveyors and crushers with high inertia require controlled acceleration to prevent material spillage and mechanical stress. The swing start mode is specifically designed for these soft starter applications.
Key benefits: Controlled acceleration, prevents material spillage, reduces belt wear
Typical configuration: 45kW-630kW for mining and material handling
Recommended soft starter models: FST-3045 (45kW), FST-3160 (160kW), FST-3630 (630kW)
Soft Starter Technical Specifications
Power Range & Model Selection
Model Power (380V) Rated Current Dimensions (mm) Weight (kg)
FST-3005 5.5kW 10A 185×348×210 8.1
FST-3007 7.5kW 15A 185×348×210 8.2
FST-3011 11kW 24A 185×348×210 8.3
FST-3015 15kW 30A 185×348×210 8.45
FST-3018 18.5kW 37A 185×348×210 8.5
FST-3022 22kW 45A 185×348×210 8.55
FST-3030 30kW 60A 185×348×210 8.6
FST-3037 37kW 75A 185×348×210 8.65
FST-3045 45kW 90A 185×348×210 8.65
FST-3055 55kW 110A 185×348×210 8.7
FST-3075 75kW 150A 185×348×210 8.8
FST-3090 90kW 180A 300×605×250 30.0
FST-3110 110kW 230A 300×605×250 30.1
FST-3132 132kW 250A 300×605×250 30.3
FST-3160 160kW 300A 300×605×250 30.4
FST-3185 185kW 360A 300×605×250 30.5
FST-3200 200kW 400A 340×661×260 42.2
FST-3225 250kW 480A 340×661×260 42.3
FST-3280 280kW 560A 340×661×260 42.5
FST-3315 315kW 640A 340×661×260 42.6
FST-3355 355kW 700A 340×661×260 42.8
FST-3400 400kW 790A 340×661×260 42.9
FST-3500 500kW 1000A 340×661×260 43.0
FST-3630 630kW 1200A 340×661×260 43.2
Electrical Specifications
  • Control Power: AC 380V (-10% to +15%), 50/60Hz (internal, no external connection needed)
  • Input Power: AC 380V (-10% to +15%), 50/60Hz
  • Motor Type: General squirrel cage 3-phase AC induction motor
  • Starting Current: 2-4× FLA (adjustable 50-600%)
  • Starting Torque: 0-90% of DOL torque (adjustable)
  • Acceleration Time: 1-120 seconds (adjustable)
  • Starting Frequency: Max 15 starts per hour (standard duty)
  • Efficiency in Bypass: >99.5% (near-zero losses)
  • Protection: Input/output phase loss, overload, overcurrent, imbalance, over/undervoltage, overheating
  • Display: Large LCD, Chinese/English, shows current, voltage, faults, parameters
  • Communication: Modbus RTU standard
  • Installation: Wall-mounted
  • Environment: -25℃ to +40℃, humidity <90% (no condensation), altitude <1000m
Soft Starter Customer Success Stories
"We replaced 12 external-bypass soft starters with FST-3000 units in our water treatment plant. The built-in design saved us 30% panel space and 2 hours wiring time per unit. The LCD display makes troubleshooting easy—technicians can see exactly what's happening without a manual. Starting current dropped from 7× to 3× FLA, eliminating voltage dips that were affecting our SCADA system."
— Li Wei, Electrical Engineer, Guangdong Water Authority
"The FST-3000's kick start mode was perfect for our air compressors. It provides the initial torque to overcome compression, then ramps smoothly. We've eliminated the mechanical shock that was damaging couplings, and the soft stop prevents reverse rotation. After 18 months of 24/7 operation, zero failures."
— Wang Tao, Maintenance Manager, Shandong Chemical Plant
Product Summary

FST-3000 built-in bypass soft starter (5.5-630kW) reduces starting current 60-70%, saves 40% panel space, and offers 6 starting modes. Integrated bypass contactor and thermal relay eliminate external components for simplified installation and near-zero energy loss in run mode.

Related Products
Contact Us
You Can Contact Us At Anytime